Three Phase Dry Type Low-Voltage Isolation Electrical Transformer SG500va

Three Phase Dry Type Low-Voltage Isolation Electrical Transformer SG500va-500kva

SG Three Phase Dry Type Isolation Transformer is a power conversion device designed for AC 50/60Hz low-voltage circuits below 1000V. Unlike oil-filled transformers, dry type transformers use air or epoxy resin as insulation, making them safer, eco-friendly, and low-maintenance.

This transformer isolates the primary and secondary circuits, preventing electrical surges, reducing electromagnetic interference, and providing stable and clean power to sensitive equipment. It is widely used in industrial control systems, low-voltage switchgear, and electrical drive equipment where reliability and safety are critical.

Type designation

MODEL: □SG□
None: lsolation, Q: Autocoupling
SS: three-phase
GDry-type transformer
Power KVA

Main technical parameter

ModelSG-500VA~500KVA
PhaseThree phase
Input voltageDefault 380V 660V 440V 220V (customizable voltage)
Output voltageDefault 220V 1140V 690V 660V 440V 415V 400V 380V 220V 110V (customizable voltage)
Voltage Accuracy±1%
Voltage variation rate≤1.5%
EfficiencyInductive (Isolated) ≥99%
Resistance to Electricity1500V/min
Overload capacityOverloading is not recommended
Ambient temperature-10°C~+ 40°C
Waveform DistortionNo additional wave form distortion
Cooling methodDry air-cooled
Connection methodD/Y Y/Y customizable
Insulating ClassClass F
Power8KVA10KVA15KVA20KVA30KVA
Size(mm)   L*W*H420*330*460460*350*520490*390*520520*430*530520*430*530
Power50KVA60KVA80KVA100KVA150KVA
Size(mm)   L*W*H750*480*780750*480*780800*500*800800*500*800800*600*800
Power200KVA250KVA300KVA400KVA500KVA
Size(mm)   L*W*H850*650*850850*650*850850*650*8501200*1000*12001200*1000*1200
The size and weight vary depending on the voltage range, and are subject to the customized actual product.

Key Applications

The Three Phase Dry Type Low-Voltage Isolation Transformer is ideal for:

  • Industrial automation → CNC machines, production lines, motors, pumps
  • Electrical drive control → Inverters, servo systems, variable frequency drives
  • Power distribution systems → Low-voltage switchgear, MCC panels, PDU cabinets
  • Renewable energy systems → Solar, wind, and battery storage integration
  • Sensitive electronics → Data centers, laboratories, medical devices
  • Commercial facilities → Malls, airports, stadiums, hospitals, and office buildings

Why Choose Our Dry Type Isolation Transformer?

Compared to conventional transformers, our Three Phase Dry Type Low-Voltage Transformers offer:

  1. Higher Safety & Reliability

Non-flammable insulation materials
No risk of oil leakage or fire hazards
Better protection against short circuits and overloads

  1. Better Power Quality

Reduces noise, harmonic distortion, and electromagnetic interference
Provides stable voltage and cleaner power output

  1. Low Maintenance & Eco-Friendly

No oil replacement required
Environmentally friendly materials and design
Compact, lightweight, and easy to install

Selection Guide

To choose the right Three Phase Dry Type Isolation Transformer, consider:

  • Rated Power (kVA) → Select a transformer 20–30% above your maximum load to handle peaks safely.
  • Input & Output Voltage → Verify compatibility with your equipment and grid voltage.
  • Load Type → For sensitive electronics, choose isolation transformers for better noise suppression.
  • Installation Environment → For dusty, humid, or confined areas, dry type transformers are the safest choice.

FAQ

Q1: What is the difference between a dry type transformer and an oil-filled transformer?
A: Dry type transformers use air or epoxy resin insulation and are safer, environmentally friendly, and easier to maintain, while oil-filled transformers require regular oil monitoring and are more suited for outdoor, high-capacity installations.

Q2: Why use an isolation transformer instead of a standard low-voltage transformer?
A: An isolation transformer separates the input and output circuits, providing better protection against voltage spikes, noise interference, and grounding issues, making it ideal for precision equipment and sensitive electronics.

Q3: What is the expected service life of this transformer?
A: With proper installation and maintenance, the Three Phase Dry Type Isolation Transformer can operate reliably for 20–30 years.